Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus
نویسندگان
چکیده
منابع مشابه
Isolated fractures of the greater tuberosity of the proximal humerus
BACKGROUND AND PURPOSE The diagnosis and treatment of isolated greater tuberosity fractures of the proximal humerus is not clear-cut. We retrospectively assessed the clinical and radiographic outcome of isolated greater tuberosity fractures. PATIENTS AND METHODS 30 patients (mean age 58 (26-85) years, 19 women) with 30 closed isolated greater tuberosity fractures were reassessed after an aver...
متن کاملLocking plate fixation for proximal humerus fractures.
Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...
متن کاملLong-term Results, Functional Outcomes and Complications after Open Reduction and Internal Fixation of Neglected and Displaced Greater Tuberosity of Humerus Fractures
Background: Humerus fractures include 5% to 8% of total fractures. Non-union and delayed union of GT (GT) fractures is uncommon; however they present a challenge to the orthopedic surgeons. Significant controversy surrounds optimal treatment of neglected fractures. The purpose of this article was to perform a comparative study to evaluate the outcomes of open reduction and internal fixatio...
متن کاملQuantitative 3-dimensional Computerized Tomography Modeling of Isolated Greater Tuberosity Fractures with and without Shoulder Dislocation
Background: The aim of this study was to assess differences in fracture morphology and displacement betweenisolated greater tuberosity (GT) fractures (i.e. fractures of the greater tuberosity without other fractures of the proximalhumerus) with and without shoulder dislocation utilizing quantitative 3-dimensional CT imaging.Methods: Thirty-four CT-scans of isolated greater tuberosity fractures ...
متن کاملAO X-shaped midfoot locking plate to treat displaced isolated greater tuberosity fractures.
Although various implants exist for 3- and 4-part fractures, few implants are appropriate for isolated greater tuberosity fractures. This retrospective study evaluated the efficacy of AO X-shaped midfoot locking plates for greater tuberosity fractures. Between May 2008 and September 2009, nineteen patients with displaced greater tuberosity fractures were treated with open reduction and internal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinics in Shoulder and Elbow
سال: 2017
ISSN: 2288-8721
DOI: 10.5397/cise.2017.20.4.222