Homograft—the optimal aortic valve substitute?

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Homograft - the optimal aortic valve substitute?

valvuloplasty can be performed safely and with satisfactory results in over 85% of these patients. It is also possible that repeat PMV can be performed in these patients with acceptable risks and results. In our own single centre experience in about 390 procedures repeat percutaneous balloon valvuloplasty was performed in 17 cases (mean age 65 13 years) without any increase in the rate of acute...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Bicuspid aortic valve; optimal diagnosis and latest interventional treatment

in BAV patients more frequently than echocardiography (96 versus 73 %); CMR appeared to be more sensitive for detecting of BAV whereas echocardiography appeared to be more specific. Among unselected patients with severe aortic valve stenosis, a high percentage of patients with BAV was found (40 %). Patients with BAV are significantly younger and more frequently male. Typically, the ascending ao...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Heart Journal

سال: 2000

ISSN: 0195-668X

DOI: 10.1053/euhj.2000.2145