Homogeneity Test on Collimators for Boron-Neutron Capture Therapy based on SNI 8506:2018
نویسندگان
چکیده
A serial homogeneity test based on Indonesian Standard SNI 8506:2018 were undertaken to investigate 12 manufactured collimators by using double wall single image radiography (DWSI) technique with an x-ray machine ranging from 120 150 kV. The standard stated that the film density should be measured seven different points, and result obtained must not exceed ± 0.05 average density. This paper outlines a testing work for collimators, calculating six points in film. Six selected due technical constrains of collimator manufacturing capabilities laboratory. results are: (1) 2.59; (2) 2.57; (3) 2.14; (4) 1.88; (5) 2.10; (6) 1.96; (7) 2.33; (8) 2.28; (9) 2.06; (10) 2.18; (11) 2.24; (12) 2.33. shows collimator-2 has most homogenous study concludes established parameters process are needed manufacture BNCT achieving proper performance standard.
منابع مشابه
Boron Neutron Capture Therapy
A project aimed at the development of an accelerator facility devoted to Boron Neutron Capture Therapy (BNCT) is ongoing at the National Atomic Energy Commission of Argentina [1]. In a first stage of development, the accelerator will be capable of delivering proton or deuteron beams of 30 mA at about 1.4 MeV which is suitable for neutron production through the 9Be(d,n) reaction. In this context...
متن کاملBoron neutron capture therapy for cancer.
*1102 Expression of Neural Cell Adhesion Molecule-related Sialoglycoprotein in Small Cell Lung Cancer and Neuroblastoma Cell Lines 1169 and CHP-212. C. E. C. Kitty Moolenaar. Egbert J. Muller, Dick J. Schol, Carl G. Figdor, Elizabeth Bock. Dieter Bitter-Suermann. and Rob J. A. M. Michalides. * 1107 Prolongation of Serum Half-Life of Interleukin 2 and Augmenta tion of Lymphokine-activated killer...
متن کاملBoron Neutron Capture Therapy for Breast Cancer
in 1960’s, but showed little development, as the thermal and epithermal neutron sources were not economical. Nuclear reactors, and recently cyclotrons are being used as neutron sources, thus enabling its widespread utilization (1). Gamma rays are utilized for the irradiation of tumor tissues, and fractional doses up to 50-60 Gray required for tumor ablation in conventional radiation therapy. Su...
متن کاملMicrodosimetry for boron neutron capture therapy.
Preclinical studies for boron neutron capture therapy (BNCT) using epithermal neutrons are ongoing at several laboratories. The absorbed dose in tumor cells is a function of the thermal neutron flux at depth, the microscopic boron concentration, and the size of the cell. Dosimetry is therefore complicated by the admixture of thermal, epithermal, and fast neutrons, plus gamma rays, and the array...
متن کاملProton Linacs for Boron Neutron Capture Therapy
Recent advances in the ability to deliver boron-containing drugs to brain tumors have generated interest in -4 MeV liiacs as sources of epithemtal neutrons for radiation therapy. In addition, fast neutron therapy facilities have been studying methods to moderate their beams to take advantage of the high cross section for epithennal neutrons on boron-10. This paper describes the technical issues...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atom Indonesia
سال: 2023
ISSN: ['0126-1568', '2356-5322']
DOI: https://doi.org/10.55981/aij.2023.1277