Historical Analysis of High Voltage Circuit Breaker Engineering

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress

In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...

متن کامل

Development of non-intrusive monitoring for reactive switching of high voltage circuit breaker

High-voltage circuit breakers are among the most important equipments for ensuring the efficient and safe operation of an electric power system. On occasion, circuit breaker operators may wish to check whether equipment is performing satisfactorily and whether controlled switching systems are producing reliable and repeatable stress control. Monitoring of voltage and current waveforms during sw...

متن کامل

Automated Analysis of Circuit Breaker Operation

In this paper a new approach to the analysis of test results for circuit breakers is discussed. It is implemented through new software called Automated Circuit Breaker Monitoring system ACBM. The circuit breaker performance is evaluated based on the analysis of Digital Fault Recorder (DFR) recordings taken from circuit breaker control circuitry. This paper describes the testing procedure and us...

متن کامل

Development of an Overall Condition Monitoring System of High Voltage SF6 Circuit Breaker

With the rapid development of arts of sensors and IT, on-line monitoring of circuit breaker is now desirable and practical for electric power utilities. This paper describes a set of overall on-line monitoring systems that was developed to control and monitor the condition of SF6 circuit breaker with different type of sensors and microcomputer based controller. The aim of the developed system i...

متن کامل

Automated Analysis of Circuit Breaker Operations

The automated circuit breaker diagnostic system described in this paper is an extension of the widely used portable circuit breaker testing device concept. These traditional testing devices can be connected to the circuit breaker’s control circuit to record analog and digital signals. The operator opens and closes the circuit breaker each time the test is performed and makes the recordings. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEJ Transactions on Fundamentals and Materials

سال: 2001

ISSN: 0385-4205,1347-5533

DOI: 10.1541/ieejfms1990.121.1_11