Histogram-Based Calibration Method for Pipeline ADCs
نویسندگان
چکیده
منابع مشابه
Histogram-Based Calibration Method for Pipeline ADCs
Measurement and calibration of an analog-to-digital converter (ADC) using a histogram-based method requires a large volume of data and a long test duration, especially for a high resolution ADC. A fast and accurate calibration method for pipelined ADCs is proposed in this research. The proposed calibration method composes histograms through the outputs of each stage and calculates error sources...
متن کاملPipeline and SAR ADCs for Advanced Nodes
The energy efficiency of ADCs has improved by orders of magnitude over the past two decades. Even though process scaling degrades the analog characteristics of transistors, by exploiting, scaling the energy efficiency of recently reported ADCs is approaching fundamental limits [1]. These improvements have been achieved through innovative circuit ideas and through the evolution of ADC architectu...
متن کاملA Digital Calibration Algorithm with Variable-amplitude Dithering for Domain-extended Pipeline Adcs
The pseudorandom noise dither (PN dither) technique is used to measure domain-extended pipeline analog-to-digital converter (ADC) gain errors and to calibrate them digitally, while the digital error correction technique is used to correct the comparator offsets through the use of redundancy bits. However, both these techniques suffer from three disadvantages: slow convergence speed, deduction o...
متن کاملEfficient digital self-calibration of video-rate pipeline ADCs using white Gaussian noise
A digital-domain self-calibration technique for video-rate pipeline A/D converters based on a white Gaussian noise input signal is presented. The implementation of the proposed algorithm requires simple digital circuitv. An application design example of the self-calibration of a IZb. 40 MUS CMOSpipeline ADC is shown to illustrate that the overall linearity of the ADC can be highly improved usin...
متن کاملHistogram-based method for contrast measurement.
A histogram-based technique for robust contrast measurement is proposed. The method is based on fitting the histogram of the measured image to the histogram of a model function, and it can be used for contrast determination in fringe patterns. Simulated and experimental results are presented.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2015
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0129736