High‐Definition Zoom Mode: A High Resolution X‐ray Microscope for Neurointerventional Treatment Procedures

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anesthetic Consideration for Neurointerventional Procedures

Interventional neuroradiology (INR) has been a rapidly expanding and advancing clinical area during the past few decades. As the complexity and diversity of INR procedures increases, the demand for anesthesia also increases. Anesthesia for interventional neuroradiology is a challenge for the anesthesiologist due to the unfamiliar working environment which the anesthesiologist must consider, as ...

متن کامل

Recent Update of Guidelines for Neurointerventional Procedures

Treatment guidelines of the neurointerventional procedures are continuously updated. However, these guidelines differ between countries and even medical societies within the same country because of the differing interests and patient groups. The differences between guidelines are confusing to many neurointerventionalists. Recently "Clinical Research Center for Stroke" in Korea updated "Clinical...

متن کامل

High-resolution scanning SQUID microscope

We have combined a novel low temperature positioning mechanism with a single-chip miniature superconducting quantum interference device ~SQUID! magnetometer to form an extremely sensitive new magnetic microscope, with a demonstrated spatial resolution of ;10 mm. The design and operation of this scanning SQUID microscope will be described. The absolute calibration of this instrument with an idea...

متن کامل

A High-resolution X-ray Microscope

92 LLE Review, Volume 74 A soft x-ray microscope (E & 3 keV) with high spatial resolution (~3 μm) has been characterized at LLE and used for initial experiments on the OMEGA laser system to study the hydrodynamic stability of directly driven planar foils. The microscope, which is an optimized Kirkpatrick-Baez (KB)–type design, is used to obtain four x-ray radiographs of laser-driven foils. Time...

متن کامل

Radiation doses to patients in neurointerventional procedures.

PURPOSE To evaluate stochastic and deterministic risks associated with neurointerventional procedures for the patient. METHODS Eight neurovascular interventional procedures were evaluated to determine the entrance skin dose and effective dose for the patient. Dosimetry was done with thermoluminescence dosimeters. The highest dose on the patient's head was recorded as the maximum entrance skin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Neuroimaging

سال: 2019

ISSN: 1051-2284,1552-6569

DOI: 10.1111/jon.12652