High-Throughput Photometric Titrimetry Based on a Feedback-based and Subsequent Fixed Triangular Wave-controlled Flow Ratiometry
نویسندگان
چکیده
منابع مشابه
High-throughput photometric titrimetry based on a feedback-based and subsequent fixed triangular wave-controlled flow ratiometry.
The principle of flow ratiometry for high-throughput titration, which we recently proposed for potentiometric titration, was extended to photometric titration. The flow rate (FB) of a base solution containing an acid-base indicator was linearly varied in response to a control voltage (Vc) generated from a computer. With the total (acid + base) flow rate (FT) being kept constant, the base soluti...
متن کاملtask-based language teaching in iran: a mixed study through constructing and validating a new questionnaire based on theoretical, sociocultural, and educational frameworks
جنبه های گوناگونی از زندگی در ایران را از جمله سبک زندگی، علم و امکانات فنی و تکنولوژیکی می توان کم یا بیش وارداتی در نظر گرفت. زبان انگلیسی و روش تدریس آن نیز از این قاعده مثتسنی نیست. با این حال گاهی سوال پیش می آید که آیا یک روش خاص با زیر ساخت های نظری، فرهنگی اجتماعی و آموزشی جامعه ایرانی سازگاری دارد یا خیر. این تحقیق بر اساس روش های ترکیبی انجام شده است.پرسش نامه ای نیز برای زبان آموزان ...
construction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
mortality forecasting based on lee-carter model
over the past decades a number of approaches have been applied for forecasting mortality. in 1992, a new method for long-run forecast of the level and age pattern of mortality was published by lee and carter. this method was welcomed by many authors so it was extended through a wider class of generalized, parametric and nonlinear model. this model represents one of the most influential recent d...
15 صفحه اولDetermination of acid/base dissociation constants based on a rapid detection of the half equivalence point by feedback-based flow ratiometry.
Acid dissociation constants (Ka) were determined through the rapid detection of the half equivalence point (EP1/2) based on a feedback-based flow ratiometry. A titrand, delivered at a constant flow rate, was merged with a titrant, whose flow rate was varied in response to a control voltage (Vc) from a controller. Downstream, the pH of the mixed solution was monitored. Initially, Vc was increase...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2005
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.21.615