High-Throughput Determination of Nicotine in Plasma by Ultrasonication Enhanced Hollow Fiber Liquid-Phase Microextraction Prior to Gas Chromatography
نویسندگان
چکیده
منابع مشابه
High-throughput determination of nicotine in plasma by ultrasonication enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.
In high-throughput ultrasonication enhanced hollow-fiber liquid-phase microextraction (H-U-HF-LPME), ultrasonication was introduced into HF-LPME to enhance the mass transfer rate of the analytes in the two immiscible liquid phases, which resulted in a very short time for extraction equilibrium and a high-throughput analysis. Several parameters were investigated and optimized (such as extraction...
متن کاملextraction and determination of fexofenadine and levocetirizine in human plasma by hollow fiber liquid phase microextraction and high performance liquid chromatography
a simple, inexpensive and efficient method was used for extraction and determination of fexofenadine and levocetirizine with three–phase hollow fiber liquid-phase microextraction and high-performance liquid chromatography. several parameters influencing the extraction recoveries such as the nature of organic extraction solvent, ph of donor and acceptor phases, stirring rate, extraction time and...
متن کاملLiquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry.
Two modes of liquid-phase microextraction (LPME) combined with hollow fiber (HF) were developed for gas chromatography/mass spectrometry (GC/MS). Both methodologies, that is, static LPME with HF and dynamic LPME with HF, involved the use of a small volume of organic solvent impregnated in the hollow fiber, which was held by the needle of a conventional GC syringe. In static LPME/HF, the hollow ...
متن کاملDetermination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملVortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography
Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chromatographic Science
سال: 2013
ISSN: 1945-239X,0021-9665
DOI: 10.1093/chromsci/bmt079