High Strength Concrete Columns under Axial Compression Load: Hybrid Confinement Efficiency of High Strength Transverse Reinforcement and Steel Fibers
نویسندگان
چکیده
منابع مشابه
High Strength Concrete Columns under Axial Compression Load: Hybrid Confinement Efficiency of High Strength Transverse Reinforcement and Steel Fibers
Addition of steel fibers to high strength concrete (HSC) improves its post-peak behavior and energy absorbing capability, which can be described well in term of toughness. This paper attempts to obtain both analytically and experimentally the efficiency of steel fibers in HSC columns with hybrid confinement of transverse reinforcement and steel fibers. Toughness ratio (TR) to quantify the confi...
متن کاملBond of High Strength Concrete with High Strength Reinforcing Steel
This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...
متن کاملBehavior of High-Strength Concrete Rectangular Columns
This paper summarizes the test results of an extensive research program sponsored by the US Transportation Research Board of the National Research Council to examine the behavior of high-strength concrete rectangular columns subjected to concentric and eccentric loading conditions. The variables considered in this investigation were concrete strength ranging from 7.9 ksi (55 MPa) to 16.5 ksi (1...
متن کاملMechanical Behavior of Hybrid Fiber Reinforced High Strength Concrete with Graded Fibers
Brittleness, which was the inherent weakness in High Strength Concrete (HSC), can be avoided by reinforcing the concrete with discontinuous fibers. Reinforcing HSC with more than one fiber is advantageous in an overall improvement of the mechanical performance of the composite. In this experimental study, Hybrid Fiber Reinforced High Strength Concrete (HyFR-HSC) mixes were formed by blending si...
متن کاملBond of Reinforcement in High-Strength Concrete
This paper describes an examination of the development of tension lap splices in high-strength concrete and the applicability of the restriction in the ACI 318 code where the values of √fc′ used to calculate development length shall not exceed 100 psi. The focus is on the development of splices with Grade 60 epoxy-coated and uncoated bars in normalweight concrete. A summary of the behavior of b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materials
سال: 2016
ISSN: 1996-1944
DOI: 10.3390/ma9040264