High speed imaging with a tapped solid state sensor
نویسندگان
چکیده
منابع مشابه
High-speed microvia formation with UV solid state lasers
Laser drilling has emerged in the last five years as the most widely accepted method of creating microvias in high-density electronic interconnect and chip packaging devices. Most commercially available laser drilling tools are currently based on one of two laser types: far-IR CO2 lasers and UV solid state lasers at 355 nm. While CO2 lasers are recognized for their high average power and drilli...
متن کاملHigh Speed, High Bandwidth External Cache Bus with A Center-Tapped-Termination Scheme
Abstract -This paper describes the implementation of an external L3 Cache memory bus used in ItaniumTM processor. The cache bus has been designed for adequate bandwidth required in high-end servers, and provides data to the processor at the processor core frequency. High-speed I/O circuits used to accomplish this state-of-the-art bus design are discussed in detail. The center-tapped-termination...
متن کاملHigh-Speed Solid State Camera Systems for Digital Photogrammetry
For many applications in machine vision, digital photogrammetry and scientific research image sequences of rapidly moving objects have to be acquired with high temporal resolution. If the standard video rate (30 frames/sec NTSC resp. 25 frames/sec CCIR) is not sufficient, high-speed solid state cameras may be considered offering frame rates of up to 15,000 frames per second. As the processing o...
متن کاملSolid state electric field sensor
Power measurement systems, such as Phasor Measurement Unit (PMU) structures, require installation of special voltage and current instrument transformers connected to the energized conductor to collect data from the power line. While non-contacting methods of current monitoring are already well known and implemented, the contactless voltage monitoring is still lacking. This paper describes a tun...
متن کاملComposite-pulse magnetometry with a solid-state quantum sensor.
The sensitivity of quantum magnetometer is challenged by control errors and, especially in the solid state, by their short coherence times. Refocusing techniques can overcome these limitations and improve the sensitivity to periodic fields, but they come at the cost of reduced bandwidth and cannot be applied to sense static or aperiodic fields. Here we experimentally demonstrate that continuous...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1990
ISSN: 0018-9499,1558-1578
DOI: 10.1109/23.106638