High Serum Free Kappa Chains Are Frequently Missed By Serum Immunofixation
نویسندگان
چکیده
منابع مشابه
Quantitation of serum free light chains does not compensate for serum immunofixation only when screening for monoclonal gammopathies.
BACKGROUND Detection of plasma cell dyscrasias (PCD) requires screening of serum and urine for monoclonal proteins. Several studies have demonstrated increased sensitivity and specificity when measurement of serum free light chain (SFLC) is part of the screening protocol. In addition, omission of immunofixation (IFE) in the standard work-up that includes SFLC assay has been proposed. This study...
متن کاملIdentification of amyloidogenic light chains requires the combination of serum-free light chain assay with immunofixation of serum and urine.
BACKGROUND The diagnosis of systemic immunoglobulin light-chain (AL) amyloidosis requires demonstration of amyloid deposits in a tissue biopsy and amyloidogenic monoclonal light chains. The optimal strategy to identify the amyloidogenic clone has not been established. We prospectively assessed the diagnostic sensitivity of the serum free light chain (FLC) kappa/lambda ratio, a commercial serum ...
متن کاملQuantitation of serum free light chains.
under usual artificial light conditions, and storage of unproc-essed whole blood without antico-agulants at room temperature on the bench. Additionally, we tested the effect of multiple freeze-thaw cycles. 25(OH)–vitamin D 3 measurements were performed on a Cobas E601 an-alyzer (Roche), using the vitamin D 3 (25-OH) assay as recommended by the manufacturer. Samples from each storage experiment ...
متن کاملSerum protein electrophoresis and immunofixation by a semiautomated electrophoresis system.
Semiautomated agarose electrophoresis and immunofixation performed with Hydrasys-Hyrys (Sebia) were compared with conventional, manually performed methods, including cellulose acetate electrophoresis, immunoelectrophoresis, and immunofixation. Reference intervals for agarose electrophoresis with Hydrasys-Hyrys were determined. Within-run imprecision (CV) for fraction quantitation with the semia...
متن کاملMonitoring serum free light chains in patients with multiple myeloma who achieved negative immunofixation after allogeneic stem cell transplantation.
Monitoring of serum free immunoglobulin light chains (FLC) in 26 myeloma patients who achieved immunofixation negativity after allografting showed a decrease of FLC at a median of 128 days before immunofixation negativity. In patients who subsequently relapsed, a 25% increase of FLC was observed at a median of 98 days before immunofixation positivity.