High-resolution PET detector design: modelling components of intrinsic spatial resolution
نویسندگان
چکیده
منابع مشابه
High-resolution PET detector design: modelling components of intrinsic spatial resolution.
The development of dedicated small animal PET (positron emission tomography) scanners has led to significantly higher spatial resolution and comparable sensitivity to clinical scanners. However, it is not clear whether we are approaching the fundamental limit of spatial resolution. This work aims to understand what is currently limiting spatial resolution during data formation and collection an...
متن کاملOnline detector response calculations for high-resolution PET image reconstruction.
Positron emission tomography systems are best described by a linear shift-varying model. However, image reconstruction often assumes simplified shift-invariant models to the detriment of image quality and quantitative accuracy. We investigated a shift-varying model of the geometrical system response based on an analytical formulation. The model was incorporated within a list-mode, fully 3D iter...
متن کاملDesign of a very high-resolution small animal PET scanner using a silicon scatter detector insert.
A small animal positron emission tomography (PET) instrument using a high-resolution solid-state detector insert in a conventional PET system was investigated for its potential to achieve sub-millimeter spatial resolution for mouse imaging. Monte Carlo simulations were used to estimate the effect of detector configurations (thickness, length and radius) on sensitivity. From this initial study, ...
متن کاملStudy of PET intrinsic spatial resolution and contrast recovery improvement for PET/MRI systems.
This paper studied PET intrinsic spatial resolution and contrast recovery improvement for PET/MRI dual modality systems. A Monte Carlo simulation tool was developed to study positron diffusion in tissues with and without a magnetic field for six commonly used isotopes ((18)F, (11)C, (13)N, (15)O, (68)Ga and (82)Rb). A convolution process was implemented to investigate PET intrinsic spatial reso...
متن کاملFinite detector based projection model for high spatial resolution.
For finite detector and focal spot sizes, here we propose a projection model for high spatial resolution. First, for a given x-ray source point, a projection datum is modeled as an area integral over a narrow fan-beam connecting the detector elemental borders and the x-ray source point. Then, the final projection value is expressed as the integral obtained in the first step over the whole focal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics in Medicine and Biology
سال: 2004
ISSN: 0031-9155,1361-6560
DOI: 10.1088/0031-9155/50/2/001