High Resolution Optical Coherence Tomography
نویسندگان
چکیده
منابع مشابه
Ultrahigh-resolution optical coherence tomography.
In the past two decades, optical coherence tomography (OCT) has been established as an adjunct diagnostic technique for noninvasive, high-resolution, cross-sectional imaging in a variety of medical fields. The rapid development of ultrabroad bandwidth light sources has recently enabled a significant improvement in OCT imaging resolution, demonstrating the potential of OCT to accomplish its orig...
متن کاملHigh-resolution imaging of gynecologic neoplasms using optical coherence tomography.
BACKGROUND A modality capable of imaging the female reproductive tract, at or near the cellular level, could lead to the detection of diseases at earlier stages than currently possible. Optical coherence tomography achieves high resolutions in the cellular range (4-20 microm) and could accomplish that level of detection. METHOD Optical coherence tomography imaging of gynecologic tissue was st...
متن کاملLarge Field, High Resolution Full-Field Optical Coherence Tomography
We present a benchmark pilot study in which high-resolution Full-Field Optical Coherence Tomography (FF-OCT) was used to image human breast tissue and is evaluated to assess its ability to aid the pathologist's management of intra-operative diagnoses. FF-OCT imaging safety was investigated and agreement between FF-OCT and routinely prepared histopathological images was evaluated. The compact se...
متن کاملReproducibility of high-resolution optical coherence tomography in multiple sclerosis.
Optical coherence tomography (OCT) is a non-invasive method to quantify neurodegeneration as an outcome in multiple sclerosis clinical trials; however, no data exist on Cirrus spectral domain optical coherence tomography (SD-OCT) reproducibility in patients with multiple sclerosis. The objective of this study was to determine the protocol for achieving optimal inter-visit, inter-rater, and intr...
متن کاملHigh-resolution frequency-domain second-harmonic optical coherence tomography.
We used continuum generated in an 8.5 cm long fiber by a femtosecond Yb fiber laser to improve threefold the axial resolution of frequency domain second-harmonic optical coherence tomography (SH-OCT) to 12 microm. The acquisition time was shortened by more than 2 orders of magnitude compared to the time-domain SH-OCT. The system was applied to image biological tissue of fish scales, pig leg ten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Lightwave Technology
سال: 2021
ISSN: 0733-8724,1558-2213
DOI: 10.1109/jlt.2021.3061606