High-Resolution MR Imaging of Muscular Fat Fraction—Comparison of Three T2-Based Methods and Chemical Shift-Encoded Imaging
نویسندگان
چکیده
منابع مشابه
High-resolution interleaved water-fat MR imaging of finger joints with chemical-shift elimination.
PURPOSE To study the use of an interleaved water-fat (IWF) sequence with a custom-made radiofrequency (RF) coil for high-resolution imaging of arthritic finger joints. MATERIALS AND METHODS High-resolution finger magnetic resonance imaging (MRI) was performed using a custom-made dedicated RF receiver coil and an IWF sequence. A phantom, a cadaver finger specimen, and the fingers of two normal...
متن کاملHigh SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging
PURPOSE To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). MATERIALS AND METHODS Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the ...
متن کاملFeasibility of T2* Estimation with Chemical Shift-Based Water-Fat Separated Cardiac Imaging
Introduction T2* mapping has been investigated in cardiac MRI for imaging the myocardial BOLD effect [1] and in iron overload assessment [2]. Advanced T2* estimation techniques in the context of chemical shift-based water-fat decomposition have recently been developed for iron detection in organs such as the liver, while simultaneously estimating fat content [3]. Separately, chemical shiftbased...
متن کاملCompressive Chemical-Shift-Based Rapid Fat/Water Imaging
Introduction: Chemical-shift based fat and water separation techniques [1,2] are very common in practice and are effective in revealing important clinical information. They require imaging at multiple echo times, which often results in additional scan time. As compressed sensing (CS) [3-5] acceleration techniques become more available, it is necessary to be able to separate between fat and wate...
متن کاملHigh Resolution T2 Breast Imaging using FADE
Introduction High-resolution 3D imaging is useful for improving the specificity of breast MRI since morphological characteristics, such as spiculations and heterogeneity, vary with histology [1]. The specificity of breast MRI can be further improved by considering physiological information such as diffusion [2]. Unlike T1-weighted contrast-enhanced imaging, it is difficult to acquire high-resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Tomography
سال: 2017
ISSN: 2379-139X
DOI: 10.18383/j.tom.2017.00011