High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment.

Rapid imaging by antitumor antibodies has been limited by the prolonged targeting kinetics and clearance of labeled whole antibodies. Genetically engineered fragments with rapid access and high retention in tumor tissue combined with rapid blood clearance are suitable for labeling with short-lived radionuclides, including positron-emitting isotopes for positron-emission tomography (PET). An eng...

متن کامل

PET imaging of CXCR4 using copper-64 labeled peptide antagonist

Expression of CXCR4 in cancer has been found to correlate with poor prognosis and resistance to chemotherapy. In this study we developed a derivative of the CXCR4 peptide antagonist, T140-2D, that can be labeled easily with the PET isotope copper-64, and thereby enable in vivo visualization of CXCR4 in tumors. T140 was conjugated to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid mono ...

متن کامل

Minibody: A novel engineered anti-carcinoembryonic antigen antibody fragment (single-chain Fv-CH3) which exhibits rapid, high-level targeting of xenografts.

A novel engineered antibody fragment (VL-VH-CH3, or "minibody") with bivalent binding to carcinoembryonic antigen (CEA) was produced by genetic fusion of a T84.66 (anti-CEA) single-chain antibody (scFv) to the human IgG1 CH3 domain. Two designs for the connecting peptide were evaluated. In the T84.66/212 LD minibody, a two-amino acid linker (generated by fusion of restriction sites) was used to...

متن کامل

SPECT- and fluorescence image-guided surgery using a dual-labeled carcinoembryonic antigen-targeting antibody.

UNLABELLED Intraoperative visualization techniques promise to significantly improve the detection and resection of tumors. In this study, we used an anti-carcinoembryonic antigen (CEA) antibody (MN-14) tagged with both a radiolabel ((111)In) and a fluorophore (IRDye 800CW) for radionuclide detection and intraoperative fluorescence imaging, respectively. METHODS For this purpose, we prepared a...

متن کامل

Testis imaging with 111In-labeled anticarcinoembryonic antigen monoclonal antibody: identification of carcinoembryonic antigen in normal germ cells.

A monoclonal antibody to carcinoembryonic antigen (CEA) labeled with 111In (Indacea) was used to image tumors in patients with colorectal cancer. The anti-CEA antibody has a high affinity (2.6 X 10(10) M-1) for CEA and does not cross-react with normal cross-reacting antigen, biliary glycoprotein-1, or tumor-extracted, CEA-related antigen. During the course of these studies, it was noted that a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Proceedings of the National Academy of Sciences

سال: 2000

ISSN: 0027-8424,1091-6490

DOI: 10.1073/pnas.150228297