High-resolution hard-X-ray fluorescence spectrometer
نویسندگان
چکیده
منابع مشابه
A Hard X - Ray Spectrometer for High Angular Resolution Observations of Cosmic Sources
LAXRIS (large area x-ray imaging spectrometer) is an experimental, balloon-borne, hard x-ray telescope that consists of a realigned array of x-ray imaging spectrometer modules capable of obtaining high angular resolution (1-3 arcminutes) with moderate energy resolution in the 20to 300-keV region. Each spectrometer module consists of a CsI(Na) crystal coupled to a position-sensitive phototube wi...
متن کاملX-ray Absorption Spectroscopy Using X–ray Fluorescence Spectrometer
Strong characteristic Kα X-ray lines are accompanied by weak lines due to the radiative Auger effect (RAE) [1, 2]. The characteristic Kα fluorescent X-rays (K-L2,3 lines) are emitted by the 2p→1s electric dipole transition after one of the 1s electron photoionization, Though the probability is less than 0.01, one of the 2p electrons is excited into an unoccupied discrete or continuum level simu...
متن کاملThe Mapping X - Ray Fluorescence Spectrometer ( Mapx
Thomas Bristow, Robert Downs, Marc Gailhanou, Franck Marchis, Douglas Ming, Richard Morris, Vicente Armando Solé, Kathleen Thompson, Philippe Walter, Michael Wilson, Albert Yen and Samuel Webb, NASA Ames Research Center, Moffett Field, CA [email protected], SETI Institute, Mountain View, CA, Univ. of Arizona, Tucson AZ, IM2NP, Université Paul Cézanne, Marseille, France, NASA Johnson Space Ce...
متن کاملHigh Resolution Hard X-ray Magnetic Imaging with Dichroic Ptychography
Claire Donnelly, 2 Valerio Scagnoli, 2, ∗ Manuel Guizar-Sicairos, Mirko Holler, Fabrice Wilhelm, Francois Guillou, Andrei Rogalev, Carsten Detlefs, Andreas Menzel, Jörg Raabe, and Laura J. Heyderman 2, † Laboratory for Mesoscopic Systems, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland Paul Scherrer Institute, 5232 Villigen PSI, Switzerland ESRF, 71 Avenue des Martyrs, 38000 Greno...
متن کاملHigh energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline.
Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed suc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2009
ISSN: 1742-6596
DOI: 10.1088/1742-6596/190/1/012035