High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
نویسندگان
چکیده
منابع مشابه
Superconducting Transition Edge Sensor for Gamma-Ray Spectroscopy
Superconducting Transition edge sensor (TES) coupled with a heavy metal absorber is a promising microcalorimeter for Gammaray (γ-ray) spectroscopy with ultra-high energy resolution and high detection efficiency. It is very useful for the non-destructed inspection of the nuclide materials. High resolving power of γ-ray peaks can precisely identify multiple nuclides such as Plutonium (Pu) and Act...
متن کاملHigh-Resolution Gamma-Ray Spectroscopy
• GEM10P4/CFG-PV4/DWR-30 Coaxial Detector System (Includes detector, cryostat, dewar, preamplifier, and 12-ft. cable pack); typical specifications: 10% relative efficiency, 1.75 keV resolution at 1.332 MeV, 41:1 peak-to-Compton ratio. • 659 0–5 keV Detector Bias Supply • 672 Spectroscopy Amplifier • 480 Pulser • C-24-12 Cables (2 ea.) • C-24-1 Cable • C-29 BNC Tee Connector • 4001A/4002D NIM Bi...
متن کاملL-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array.
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are i...
متن کاملHigh-resolution molybdenum K-edge X-ray absorption spectroscopy analyzed with time-dependent density functional theory.
X-ray absorption spectroscopy (XAS) is a widely used experimental technique capable of selectively probing the local structure around an absorbing atomic species in molecules and materials. When applied to heavy elements, however, the quantitative interpretation can be challenging due to the intrinsic spectral broadening arising from the decrease in the core-hole lifetime. In this work we have ...
متن کاملHigh-resolution NMR spectroscopy with a portable single-sided sensor.
We report construction of a portable nuclear magnetic resonance sensor with a single-sided open probe design. The resulting magnetic field inhomogeneity is compensated by a pulse sequence that takes advantage of parallel inhomogeneity in the applied radio frequency field. We can thereby acquire fluorine-19 spectra of liquid fluorocarbons with 8 parts per million resolution, surmounting the long...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics Letters
سال: 2013
ISSN: 0003-6951,1077-3118
DOI: 10.1063/1.4829156