منابع مشابه
High-Resolution Light-Field Microscopy
By combining a high-resolution image from a standard camera with a low-resolution wavefront measurement from a Shack-Hartmann sensor, we numerically reconstruct a highresolution light field. We experimentally demonstrate the method with a commercially available microscope. ©2013 Optical Society of America OCIS codes: (110.0180) Microscopy; (110.1758) Computational imaging; (100.6640) Superresol...
متن کاملHigh Resolution 3D Intracranial Imaging at 3.0T
Introduction Vessel wall imaging of intracranial arteries is challenging due to their small sizes and their relatively deep locations inside the brain. 3D Time-of-flight (TOF) and contrast enhanced MRA (ceMRA) are commonly used [1] luminographic techniques. They lack specificity as luminal defects may be caused by various reasons. Dark blood, two dimensional turbo spin echo (2DTSE) has been use...
متن کاملMicroscopy with microlens arrays: high throughput, high resolution and light-field imaging.
We demonstrate highly parallelized fluorescence scanning microscopy using a refractive microlens array. Fluorescent beads and rat femur tissue are imaged over a 5.5 mm x 5.5 mm field of view at a pixel throughput of up to 4 megapixels/s and a resolution of 706 nm. We also demonstrate the ability to extract different perspective views of a pile of microspheres.
متن کامل3D Submillimeter-Resolution Reduced-Field-of-View Diffusion Tensor Imaging
Introduction For better delineation of neuronal architecture, higher spatial resolution is always desirable. Challenges in realization of high spatial resolution include but are not limited to long total scan time, low signal-to-noise ratio (SNR), and high sensitivity to T2* blurring, off-resonance, and motion-related artifacts. In the present work, the reduced field-of-view (rFOV) imaging appr...
متن کاملDetermining 3D Flow Fields via Multi-camera Light Field Imaging
In the field of fluid mechanics, the resolution of computational schemes has outpaced experimental methods and widened the gap between predicted and observed phenomena in fluid flows. Thus, a need exists for an accessible method capable of resolving three-dimensional (3D) data sets for a range of problems. We present a novel technique for performing quantitative 3D imaging of many types of flow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomedical Optics
سال: 2020
ISSN: 1083-3668
DOI: 10.1117/1.jbo.25.10.106502