منابع مشابه
Effect of Sodium Dodecyl Sulfate on Copper Anodic Dissolution in Phosphoric Acid Solution
In Electrochemical Mechanical Planarization process (ECMP), concentrated phosphoric acid is usually used as electrolyte. Role of sodium dodecyl sulfate (SDS) in anodic dissolution of Cu in concentrated phosphoric acid was studied by Cyclic Voltammetry (CV), inhibition efficiency (IE) calculation and in-situ observation of the Cu electrode surface at anodic overpotentials. It was found that pres...
متن کاملEnhancement of Dissolution Rate of Indomethacin Using Liquisolid Compacts
The potential of liquisolid systems to improve the dissolution properties of a water-insoluble agent (indomethacin) was the purpose of this survey. In this study, different formulations of liquisolid tablets using different co-solvents (non-volatile solvents) were prepared and the effect of several amounts of them on the dissolution behaviour of indomethacin was investigated. It is worth mentio...
متن کاملFactors Affecting Dissolution Rate
Solubility of drug plays a prime role in controlling its dissolution from dosage form. Aqueous solubility of drug is a major factor that determines its dissolution rate. Minimum aqueous solubility of 1% is required to avoid potential solubility limited absorption problems. Studies of 45 compound of different chemical classes and a wide range of solubilities revealed that initial dissolution rat...
متن کاملEnhancement of Dissolution Rate of Indomethacin Using Liquisolid Compacts
The potential of liquisolid systems to improve the dissolution properties of a water-insoluble agent (indomethacin) was the purpose of this survey. In this study, different formulations of liquisolid tablets using different co-solvents (non-volatile solvents) were prepared and the effect of several amounts of them on the dissolution behaviour of indomethacin was investigated. It is worth mentio...
متن کاملDisposable Copper-Based Electrochemical Sensor for Anodic Stripping Voltammetry
In this work, we report the first copper-based point-of-care sensor for electrochemical measurements demonstrated by zinc determination in blood serum. Heavy metals require careful monitoring, yet current methods are too complex for a point-of-care system. Electrochemistry offers a simple approach to metal detection on the microscale, but traditional carbon, gold (Au), or platinum (Pt) electrod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of The Electrochemical Society
سال: 1969
ISSN: 0013-4651
DOI: 10.1149/1.2411528