High performance liquid chromatographic assay of neothramycin in biological fluids.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gas--liquid chromatographic assay of aminoglutethimide and a high-performance liquid chromatographic assay for its acetyl metabolite in biological fluids.

A rapid, sensitive and selective gas--liquid chromatographic assay for aminoglutethimide is described. The same extraction procedure may be employed prior to a high-performance liquid chromatographic assay for acetamidoglutethimide which is also detailed. Both assays are suitable for the study of the pharmacokinetics of aminoglutethimide and acetamidoglutethimide in biological fluids in man.

متن کامل

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

High-performance Liquid Chromatographic Determination of Colchicine in Pharmaceutical Formulations and Biological Fluids

Results: The linear regression analysis data for calibration curve showed a good relationship with correlation coefficient of 0.9997. The concentration range was 7-130 μg/ml. The percentage recovery of COLC was found to be 99.87 %. The limits of detection and quantification are also reported. This selective method is found to be accurate, precise and effectively used for the determination of CO...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

High-performance liquid chromatographic separation and quantitation of nucleosides in urine and some other biological fluids.

Precise, quantitative high-performance liquid chromatography of samples equivalent to 25 l of urine can be done in less than 1 h with excellent resolution and recovery of pseudouridine, 1-methyladenosine, 1-methylinosine, N2-methylguanosine, adenosine, and N2,N2-dimethylguanosine. These six nucleosides are present in normal urine in concentrations ranging from 0.4 to 60 mg/liter. The use of an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Antibiotics

سال: 1981

ISSN: 0021-8820,1881-1469

DOI: 10.7164/antibiotics.34.845