منابع مشابه
Quantification of Ultrasound Contrast Agents Using High Frequency Ultrasound
Ultrasound contrast agents (UCAs) are small microbubbles filled with gas. Because of their scattering properties, UCAs enhance the diagnostic capabilities of ultrasonic imaging. UCAs are associated with therapeutic or enhancing therapeutic applications of ultrasound and with possible adverse bioeffects. Quantification of the in vivo concentration of microbubbles is therefore essential to establ...
متن کاملNon-invasive high-frequency vascular ultrasound elastography.
Non-invasive vascular elastography (NIVE) was recently introduced to characterize mechanical properties of superficial arteries. In this paper, the feasibility of NIVE and its applicability in the context of high-frequency ultrasound imaging is investigated. First, experiments were performed in vitro on vessel-mimicking phantoms. Polyvinyl alcohol cryogel was used to create two double-layer ves...
متن کاملSchlieren metrology for high frequency medical ultrasound.
The increased use of medical ultrasound above 40 MHz poses the challenge of measuring beam features that may be less than 40 microm. We have successfully used the optical Schlieren technique for transducers operating as high as 110 MHz. After a brief discussion of the technique, results are presented, including comparisons to state-of-the-art hydrophones and wire targets.
متن کاملPassive Materials for High Frequency Ultrasound Transducers
In this paper, the elastic properties of passive materials (matching, backing and lens materials) for ultrasound transducers are explored at room temperature in the frequency range of 25-65MHz using the ultrasonic spectroscopy method. AlurninaJEPOTEK 301 and tungsten/EPO-TEK 301 composites were fabricated and measured. Experimental results display a monotonic rise in acoustic impedance of the c...
متن کاملHigh-frequency ultrasound-responsive block copolymer micelle.
Micelles of a diblock copolymer composed of poly(ethylene oxide) and poly(2-tetrahydropyranyl methacrylate) (PEO-b-PTHPMA) in aqueous solution could be disrupted by high-frequency ultrasound (1.1 MHz). It was found that, upon exposure to a high-intensity focused ultrasound (HIFU) beam at room temperature, the pH value of the micellar solution decreased over irradiation time. The infrared spectr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Ophthalmology
سال: 1995
ISSN: 0007-1161
DOI: 10.1136/bjo.79.11.967