High-frequency respiratory input impedance measurements in infants assessed by the high speed interrupter technique
نویسندگان
چکیده
منابع مشابه
Respiratory input impedance during high frequency oscillatory ventilation.
Total respiratory input impedance (Zrs) measured by forced excitation may be computed easily from pressure and flow measurements recorded at the airway opening. The purpose of this paper was to analyse how the information provided by Zrs may be used for monitoring ventilatory mechanics during high frequency oscillatory ventilation (HFOV). We measured impedance (0.125-32 Hz) in six dogs, and in ...
متن کاملA New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to150 kHz
Grid impedance estimation is used in many power system applications such as grid connected renewable energy systems and power quality analysis of smart grids. The grid impedance estimation techniques based on signal injection uses Ohm’s law for the estimation. In these methods, one or several signal(s) is (are) injected to Point of Common Coupling (PCC). Then the current through and voltage of ...
متن کاملHigh Speed Trash Measurements
This paper discusses the identification of trash objects in cotton using machine vision-based systems. Soft computing techniques such as neural networks and fuzzy inference systems can classify trash objects into individual categories such as bark, stick, leaf, and pepper trash types with great accuracies. High speed trash measurements, enables the implementation of these techniques for on-line...
متن کاملPhase Frequency Detector Using Transmission Gates for High Speed Applications
In this paper a new phase-frequency detector is proposed using transmission gates which can detect phase difference less than 500ps. In other word, the proposed Phase-frequency Detector (PFD) can work in frequencies higher than 1.7 GHz, whereas a conventional PFD operates at frequencies less than 1.1 GHz. This new architecture is designed in TSMC 0.13um CMOS Technology. Also, the proposed PFD a...
متن کاملEvaluation of the interrupter technique in healthy, unsedated infants.
The interrupter technique may be used to monitor respiratory resistance and does not require active patient cooperation, but has yet to be applied in unsedated, spontaneously breathing infants. The aim of this study was to determine if the interrupter technique is feasible in spontaneously breathing infants and to investigate the influence of facemask types and analysis techniques on the interr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Respiratory Journal
سال: 1998
ISSN: 0000-0000,0903-1936
DOI: 10.1183/09031936.98.12010148