High-frequency Oscillatory Ventilation in Children: A 10-year Experience

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-frequency oscillatory ventilation in children: a 10-year experience.

OBJECTIVES The aim of the study was to describe the experience with high-frequency oscillatory ventilation (HFOV) in a Portuguese Pediatric Critical Care Unit, and to evaluate whether HFOV allowed improvement in oxygenation and ventilation. METHODS This was a retrospective observational cohort study of children ventilated by HFOV between January, 2002 and December, 2011. The following paramet...

متن کامل

High-frequency oscillatory ventilation in children: a single-center experience of 53 cases

INTRODUCTION The present article reports our experience with high-frequency oscillatory ventilation (HFOV) in pediatric patients who deteriorated on conventional mechanical ventilation. METHODS The chart records of 53 consecutively HFOV-treated patients from 1 January 1998 to 1 April 2004 were retrospectively analyzed. The parameters of demographic data, cause of respiratory insufficiency, Pe...

متن کامل

high frequency oscillatory ventilation in severe respiratory failure

despite improvement of mechanical ventilation devices for infants, lung injury still causes morbidity and mortality in many cases. to determine the effect of high frequency oscillatory ventilation (hfov) in infants with severe respiratory failure, 10 neonates were evaluated prospectively. mean gestational age of these patients was 35 weeks and alveolar-arterial oxygen gradient (a-ado2) and the ...

متن کامل

High-frequency oscillatory ventilation in pediatric patients.

HFOV is a mode of ventilation that can achieve oxygenation and ventilation while maintaining maximal lung recruitment on the deflation limb of its pressure-volume curve. The primary theoretical advantages of HFOV over CMV in the management of acute lung injury are that HFOV allows adequate alveolar ventilation with minimal peak-trough pressure changes, provides lung recruitment, and avoids end-...

متن کامل

High-frequency oscillatory ventilation on shaky ground.

We thought it was impossible. Physiological principles maintained that ventilation at tidal volumes less than the anatomical deadspace should be ineffective (i.e., inspired air not reaching the alveolae). Data from a 1980 study dispelled that myth, showing unequivocally that ventilation with tidal volumes as small as 20 to 30 ml in dogs, a mere fraction of the anatomical deadspace, could mainta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jornal de Pediatria

سال: 2013

ISSN: 0021-7557

DOI: 10.1016/j.jped.2013.02.008