High Frequency Model of Oil-immersed Transformer and Lightning Surge Analysis
نویسندگان
چکیده
منابع مشابه
consequence analysis of the leakage, ignition and explosion during high pressure sour gas injection process to the oil reservoir
there is no doubt that human being needs to become integrated with industry and industry needs to be progressed, daily. on the other hand, serious events in industrial units specially in oil industries has been shown that such damages and events are industry related ones. the consequence of such events and damages which resulted in chemical and poisoned explosions and loss of life and property ...
Identification of high frequency transformer model parameters
A two stage model is used to model the high frequency transient behavior of two winding transformers. The assumed transformer model’s parameters are estimated using the maximum likelihood estimation technique and the Kalman filter based on the time response data. Simulations are carried out using the frequency response data generated based on an assumed transformer model. The transfer function ...
متن کاملPerformance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer
Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...
متن کاملA High Frequency Transformer Winding Model for FRA Applications
Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...
متن کاملLightning Surge Analysis on Grounding Models of a Transmission Lines
Lightning has been one of the important problems for insulation design of power systems and it is still the main cause of outages of transmission and distribution lines. The lightning return-stroke current and the charge delivered by the stroke are the most important parameters to assess the severity of lightning strokes to power lines and apparatus. In order to calculate lightning surge analys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1999
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1990.119.8-9_925