High flux photon beam monitor

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photon Flux Monitor for a Mono-energetic Gamma Ray Source

A novel photon flux monitor has been designed and tested for use at the Duke University High Intensity Gamma Source, where the photon beam produced is essentially mono-energetic but it is not tagged. Direct counting of the number of photons using a high-efficiency detector is not possible because of the high photon fluxes expected. Therefore, a direct counting detector with a low, accurately kn...

متن کامل

A Versatile High Resolution Beam Position Monitor*

A new kind of Cerenkov beam position monitor is described. The counter, though relatively simple and inexpensive, has high sensitivity, introduces a minimal amount of multiple scattering, and is capable of high spatial resolution over a wide range of beam currents 0 Measurements of the position of the SLAC electron beam to an accuracy of I l/2 mm have been made for electron currents from 20 nA ...

متن کامل

A Single-pass Beam Position Monitor for the Injection Beam at the Photon Factory Storage Ring

A single-pass beam-position monitor (BPM) system to measure the injection-beam positions in the storage ring was developed. Bipolar bunch signals extracted through button electrodes were recorded in real time using a high-speed waveform digitizer, and the beam positions were determined from the amplitudes of the bipolar signals. The beam positions at 8 BPMs were measured at the same time by mea...

متن کامل

Beam Intensity Profile Monitor

This paper describes an intercepting beam intenSity profile and position monitor which was developed at SLAC. It has excellent spatial resolution as well as signal efficiency. The instrument utilizes the electromagnetic cascade shower emission effect. Net charge leakage signals comparable in magnitude to the intercepted beam current are easily obtainable. The latest model of the instrument is d...

متن کامل

RIBE Flux vs. Position Monitor

Recent work at SNL has demonstrated unique capabilities to experimentally measure a variety of ion and neutral particle parameters inside surface features being etched, including ion energy, angular distributions, ion and neutral species measurements. This report details the construction of one recent laboratory tool designed to measure ion beam uniformity over the wafer surface in a reactive i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1986

ISSN: 0168-9002

DOI: 10.1016/0168-9002(86)90115-4