High-flux hydrogen irradiation-induced cracking of tungsten reproduced by low-flux plasma exposure
نویسندگان
چکیده
منابع مشابه
Nanostructured fuzz growth on tungsten under low-energy and high-flux He irradiation
We report the formation of wave-like structures and nanostructured fuzzes in the polycrystalline tungsten (W) irradiated with high-flux and low-energy helium (He) ions. From conductive atomic force microscope measurements, we have simultaneously obtained the surface topography and current emission images of the irradiated W materials. Our measurements show that He-enriched and nanostructured st...
متن کاملhigh-flux and low-flux membranes: efficacy in hemodialysis
results the mean kt/v was 1.27 ± 0.28 in high-flux and 1.10 ± 0.32 in low-flux membrane which, these differences were statistically significant (p = 0.017). the mean of urr was 0.65 ± 0.09 in high-flux and 0.61 ± 0.14 in low-flux membrane, which these differences were not statistically significant (p = 0.221). patients and methods forty hemodialysis patients participated in this cross-over clin...
متن کاملEffect of high-flux, low-energy He+ ion irradiation on Ta as a plasma-facing material
The goal of this work is to assess Ta as a potential plasma-facing material for future fusion reactors in terms of its response to high-flux, low-energy He+ ion irradiation. Ta samples were irradiated with 100 eV He+ ions at various fluences up to 3.5 × 1025 ions m-2 while simultaneously heated at constant temperatures in the range 823-1223 K. SEM studies show that irradiated Ta surfaces underg...
متن کاملHigh-Flux and Low-Flux Membranes in Hemodialysis
Background: Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that highflux membrane improves removal of moderatemolecules while other studies no significant on them. Objectives: The aim of this study was to investigate the dialysis adequacy of low-flux versus high-flux membranes in Hemodialysis Patients. Patients and Methods: Forty ...
متن کاملHigh-Flux and Low-Flux Membranes: Efficacy in Hemodialysis
BACKGROUND Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that high-flux membrane improves the removal of moderate-sized molecules while other studies indicate no significant effect on them. OBJECTIVES This study aimed to investigate the dialysis efficacy of low-flux versus high-flux membranes in hemodialysis patients. PATIENT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Fusion
سال: 2019
ISSN: 0029-5515,1741-4326
DOI: 10.1088/1741-4326/ab0915