High Definition X-Ray Fluorescence: Principles and Techniques
نویسندگان
چکیده
منابع مشابه
High-resolution X-ray fluorescence and excitation spectroscopy of metalloproteins.
A spectrograph has been developed with sufficient efficiency to make high-resolution fluorescence experiments on metalloproteins possible. The resolution of this spectrometer can reach 0.45 eV at 7.1 keV emission energy. The focus images of this multiple curved-crystal array spectrometer are presented. The chemical sensitivity of Kbeta emission spectra can be used to identify chemical states, a...
متن کاملThe effect of nurses' virtual learning on knowledge and practice of observing X-Ray protection principles
Background: Upgrading the level of staffs knowledge in this regard can play an important role in reducing the complications of radiation in the community. Materials and Methods: This randomized clinical trial was coducted on 90 nurses. To collect data, a demographic information form and a radiation protection and X-ray protective questionnaire and a performance checklist were used. Education...
متن کاملHigh magnetic field techniques for neutron and X-ray scattering
2014 Since 1968 Oxford Instruments has been at the forefront of the manufacture of not only reliable high field superconducting magnets but also low temperature systems for research institutes throughout the world. The succeeding years have been a period of fruitful symbiosis between technological progress, in particular the development of new materials, and the increasingly stringent demands o...
متن کاملHigh-throughput X-ray techniques and drug discovery.
In the past two decades the promise of structure-based drug design has continued to attract significant interest from the pharmaceutical industry. The initial wave of enthusiasm in the late eighties resulted in some notable successes, for example, the crystal structures of HIV protease and influenza neuraminidase were used to design Viracept and Relenza, both drugs currently used in anti-viral ...
متن کاملX-ray Absorption Spectroscopy Using X–ray Fluorescence Spectrometer
Strong characteristic Kα X-ray lines are accompanied by weak lines due to the radiative Auger effect (RAE) [1, 2]. The characteristic Kα fluorescent X-rays (K-L2,3 lines) are emitted by the 2p→1s electric dipole transition after one of the 1s electron photoionization, Though the probability is less than 0.01, one of the 2p electrons is excited into an unoccupied discrete or continuum level simu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: X-Ray Optics and Instrumentation
سال: 2008
ISSN: 1687-7632,1687-7640
DOI: 10.1155/2008/318171