منابع مشابه
High accuracy dual lens transmittance measurements.
We show how to determine the transmittance of short focal length lenses (f approximately 19 mm and f approximately 2 5 mm, in this case) with a combined uncertainty of 3 parts in 10(4) or better by measuring transmittances of lens pairs of a set of three or more lenses with the same nominal focal length. Uncertainties are minimized by optimizing the radiometric design of the setup and the measu...
متن کاملThe settling-time reducibility ordering
To each computable enumerable (c.e.) set A with a particular enumeration {As}s∈ω, there is associated a settling function mA(x), where mA(x) is the last stage when a number less than or equal to x was enumerated into A. One c.e. set A is settling time dominated by another set B (B >st A) if for every computable function f , for all but finitely many x, mB(x) > f(mA(x)). This settling-time order...
متن کاملLow Settling Time All Digital DLL For VHF Application
Settling time is one of the most important parameter in design of DLLs. In this paper we propose a new high speed with low settling time Delay Locked Loop (DLL) in which a digital signal processor (DSP) is used instead of using phase-frequency detector, charge pump and loop filter in conventional DLL. To have better settling time, PRP conjugate gradient algorithm is used to optimize delay of ea...
متن کاملHigh accuracy polarization measurements using binary polarization rotators.
We report a novel system for the accurate measurement of all polarization related parameters, including polarization mode dispersion and polarization dependent loss, using binary magneto-optic polarization rotators. By taking advantage of the binary nature of the rotators, we achieved unprecedented DGD, SOPMD, and PDL accuracies of 2.6 fs, 1.39ps(2), and 0.06 dB respectively; repeatabilities of...
متن کاملNarrow Line Rubidium Magnetometer for High Accuracy Field Measurements
Observations of Zeeman tansitions in Rb87 vapor can be used to make accurate measurements of the earth's magnetic field provided that the resonance lines are narrow enough so that the separate components of the transitions are resolved. However, the resulting relatively low signal-to-noise ratio makes it difficult to follow rapid chages in the field. Self-oscillating magnetometers have rapid re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 1983
ISSN: 0018-9456,1557-9662
DOI: 10.1109/tim.1983.4315003