High accuracy AC current sources calibration by single junction thermal converters at INM
نویسندگان
چکیده
The National Metrology Institute of Colombia (INM) uses high accuracy calibrators (such as Fluke 5720A/5730A) AC current reference standards. We describe the implementation at INM AC-DC transfer standards by single junction thermal converters (SJTC) to improve measurements and give traceability International System Units (SI) within country. measurement model, present uncertainty budget estimation accordingly Guide Expression Uncertainty in Measurement (GUM) analyze effect temperature electrostatic on measurements. Expanded uncertainties between 68 μA/A 2.6 mA/A were obtained for calibration transconductance amplifiers currents from 5 mA 20 A (40 Hz kHz). results are compatible with Institutes like Centro Nacional de Metrología Mexico (CENAM) Accredited Laboratories Fluke.
منابع مشابه
AC-DC Difference Characteristics of High- Voltage Thermal Converters
This paper describes a study of high-voltage thermal converters (HVTC's) at voltages above 100 V at frequencies up to 100 kHz. Techniques for the construction of HVTC's are described, and the effects of aging and dielectric loss on the resistor, changes in the timing sequence of ac-dc difference tests, relay dead-times, warmup times, and voltage level dependence are given.
متن کاملThermal Converters as AC-DC Transfer Standards for Current and Voltage Measurements at Audio Frequencies
Thermal converters and associated equipment that are used as ac-dc transfer standards at the National Bureau of Standards for the precise measurement of current and voltage at power and audio frequencies are described. The standards and the equipment are primarily used to standardize a-c ammeters and voltmeters submitted to the Bureau for certification. The ac-dc transfer may be made with these...
متن کاملA New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress
An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...
متن کاملCalibration of Non Quadratic Sensibility Thermal Converters
A measurement system for the ac-dc transfer difference of thermal converters whose power response is not exactly quadratic is presented. The previous method, due to the simplifications of the equations, was not valid for those ac-dc transfer standards with a sensibility slightly different from 2. The error in using these equations for those standards has been evaluated and can be as high as 20 ...
متن کاملThermal Management of High-Current Bidirectional Isolated DC-DC Converters
To my family i ACKNOWLEDGMENTS The research presented in this thesis was conducted at Delft University of Technology, the Netherlands, in the Electrical Power Processing (EPP) group headed by Professor Braham Ferreira. This is the place where I spent six memorable years towards my Master and Ph.D. degrees. Many people have been involved during this time and this thesis would not be completed wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dyna-colombia
سال: 2021
ISSN: ['0012-7353', '2346-2183']
DOI: https://doi.org/10.15446/dyna.v88n216.86244