Heterodyne two beam Gaussian microscope interferometer
نویسندگان
چکیده
منابع مشابه
Heterodyne interferometer with unequal path lengths
Laser interferometry is an extensively used diagnostic for plasma experiments. Existing plasma interferometers are designed on the presumption that the scene and reference beam path lengths have to be equal, a requirement that is costly in both the number of optical components and the alignment complexity. It is shown here that having equal path lengths is not necessary, instead, what is requir...
متن کاملHeterodyne displacement interferometer, insensitive for input polarization.
Periodic nonlinearity (PNL) in displacement interferometers is a systematic error source that limits measurement accuracy. The PNL of coaxial heterodyne interferometers is highly influenced by the polarization state and orientation of the source frequencies. In this Letter, we investigate this error source and discuss two interferometer designs, designed at TU Delft, that showed very low levels...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملNonlinearity in a fiber-optic coupled heterodyne interferometer
A high-accuracy (nonlinearity < 2nm) fiber-optic coupled displacement heterodyne measuring Michelson interferometer is developed. The primary limitation of accuracy encountered with this fiber-optic coupled heterodyne interferometer is the optical mixing arising from the imperfection of fiber-optic coupling system. The optical mixing results in the nonlinearity (first order and second order err...
متن کاملSimple heterodyne laser interferometer with subnanometer periodic errors.
We describe a simple heterodyne laser interferometer that has subnanometer periodic errors and is applicable to industrial fields. Two spatially separated beams can reduce the periodic errors, and the use of a right-angle prism makes the optical configuration much simpler than previous interferometers. Moreover, the optical resolution can be enhanced by a factor of 2, because the phase change d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2007
ISSN: 1094-4087
DOI: 10.1364/oe.15.008346