Heterodyne interferometer with unequal path lengths

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heterodyne interferometer with unequal path lengths

Laser interferometry is an extensively used diagnostic for plasma experiments. Existing plasma interferometers are designed on the presumption that the scene and reference beam path lengths have to be equal, a requirement that is costly in both the number of optical components and the alignment complexity. It is shown here that having equal path lengths is not necessary, instead, what is requir...

متن کامل

Heterodyne common-path grating interferometer with Littrow configuration.

This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0....

متن کامل

Space position measurement using long-path heterodyne interferometer with optical frequency comb.

A heterodyne interference system was developed for position measurement. A stabilized optical-frequency comb is used as the laser source. The preliminary experiment to measure a distance of 22.478 m shows a drift of 1.6 μm in 20 minutes after the temperature compensation. Comparison and frequency shift experiments have been done for a distance of about 7.493 m. The experimental results show tha...

متن کامل

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

We describe a free-space common-path polarization Sagnac interferometer. The polarization Sagnac interferometer is used in a symmetric fashion with detection on the dark fringe of the interference to avoid photodetector saturation when high-powered illumination is used. By modulating the carrier field that is reflected from the interferometer, we generate a local oscillator for heterodyne detec...

متن کامل

Heterodyne displacement interferometer, insensitive for input polarization.

Periodic nonlinearity (PNL) in displacement interferometers is a systematic error source that limits measurement accuracy. The PNL of coaxial heterodyne interferometers is highly influenced by the polarization state and orientation of the source frequencies. In this Letter, we investigate this error source and discuss two interferometer designs, designed at TU Delft, that showed very low levels...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2006

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.2336769