HEPA FILTER MATERIAL LOAD DETECTION USING A MICROWAVE CAVITY SENSOR
نویسندگان
چکیده
منابع مشابه
Hepa Filter Material Load Detection Using a Microwave Cavity Sensor
This paper presents a novel microwave cavity sensor application for the detection of HEPA filter particulate loading. The sensor resonates at 3.435GHz and 8.570GHz when empty, where the TM010 and TM020 modes dominate respectively. Experimental results show that the resonant frequency of the sensor shifts significantly when filters of different particulate loadings are presented to it. This is a...
متن کاملHEPA EXHAUST FILTER IV HEPA SUPPLY FILTER I / All
A microbiological survey of the effectiveness of class II (laminar flow) 'safety' cabinets found in the UK in the last six years is recorded. Only two of the nine units tested approached the containment of aerosols achieved by a good class I (exhaust protective) cabinet. The others were potentially hazardous if used with pathogenic material. The National Sanitation Foundation and the British St...
متن کاملA Compact Microwave Microfluidic Sensor Using a Re-Entrant Cavity
A miniaturized 2.4 GHz re-entrant cavity has been designed, manufactured and tested as a sensor for microfluidic compositional analysis. It has been fully evaluated experimentally with water and common solvents, namely methanol, ethanol, and chloroform, with excellent agreement with the expected behaviour predicted by the Debye model. The sensor's performance has also been assessed for analysis...
متن کاملMicrowave Coupled-Line Sensor Allowing for Detection of Material Permittivity
A novel method of dielectric sample detection utilizing microwave coupled-line sensor has been presented. The proposed measurement setup composed of two identical baluns and coupled-line section covered by an unknown material has been analyzed and formulas allowing for calculation of effective permittivity have been derived along with simplified calibration procedure. The method allows for dete...
متن کاملMicrowave Chemical Sensor Using Substrate-Integrated-Waveguide Cavity
This research proposes a substrate-integrated waveguide (SIW) cavity sensor to detect several chemicals using the microwave frequency range. The frequency response of the presented SIW sensor is switched by filling a very small quantity of chemical inside of the fluidic channel, which also causes a difference in the effective permittivity. The fluidic channel on this structure is either empty o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal on Smart Sensing and Intelligent Systems
سال: 2010
ISSN: 1178-5608
DOI: 10.21307/ijssis-2017-395