Hemolysis in the Starr-Edwards aortic prostheses
نویسندگان
چکیده
منابع مشابه
Acute dysfunction of Starr-Edwards mitral prostheses.
Four cases of acute dysfunction of Starr-Edwards mitral prostheses are recorded. The patients presented with sudden dyspnoea 4 to 18 months after apparently successful mitral valve replacement. The prosthetic valve dysfunction was caused by thrombus on the bare metal cage of the prosthesis. No warning thromboembolic phenomena had been recorded. Urgent replacement of the valve resulted in the su...
متن کاملFunctional results with aortic ball valve prostheses (Starr-Edwards) followed for two to three years.
It is now believed that aortic insufficiency and calcific aortic stenosis must be treated with total valve replacement. Until recently this was performed with the aid of prostheses of teflon and similar materials. Even if the short-term results were promising, follow-up studies revealed a high percentage of breakdown of these prostheses (Bjork, Cullhed, and Lodin, 1963; Larson and Kirklin, 1964...
متن کاملChronic hemolysis following fascia lata and Starr-Edwards aortic valve replacement.
Sixty-two patients were investigated for chronic intravascular hemolysis from 3 months to 6iS years following aortic valve replacement; 27 patients had Starr-Edwards prostheses and 35 fascia lata grafts. The findings are suggestive of a significantly higher incidence and degree of hemolysis in patients with Starr-Edwards prostheses compared to those with fascia lata grafts. In both groups regur...
متن کاملTen year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.
The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from ...
متن کاملThe Starr-Edwards valve.
This report reviews the results obtained with the current models of the Silastic ball valve, classifying the experience with the mitral and aortic models into the periods (formula: see text) before and after 1973. Valve failure is defined according to the Stanford method and includes any valve-related death or complication necessitating valve removal (there have been no mechanical failures). Co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The American Journal of Cardiology
سال: 1973
ISSN: 0002-9149
DOI: 10.1016/0002-9149(73)90988-0