Heating performance of heating floor integrated with impinging jet ventilation system

نویسندگان

چکیده

Radiant floor heating systems provide comfortable indoor thermal environment. Primary air supply can be used to remove contaminants in the space heated by radiant floor. In this study, performance of integrated system impinging jet ventilation (IJV) and was numerically investigated. The lowest capacity 0 W/m 2 gradually increased 50W/m , primary temperature supplied IJV were 14, 16 18°C, respectively. terms contaminant removal efficiency, efficiency (CRE) applied. vertical dimensionless distribution analyse HF on air. numerical results showed that layer could 60% 80% under heat effect HF. same is true for low 14 °C. IJV/HF generated weaken stratification which beneficial energy saving. CRE influenced downward airflow external wall. Sufficient overcome downflow effectively increase value (> 2).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Building Integrated Heating Systems

This paper presents the preliminary modelling perspectives of an ongoing project where a flexible simulation tool for component and system analysis of district heating consumer installations is developed. The simulation tool makes it possible to simulate district heating consumer installations containing water based central heating systems, domestic hot tap water systems, buildings as well as l...

متن کامل

Ceramic panel heating under impinging methane-air premixed flame jets

Due to the ever wider use of composite materials within aerospace applications, fireproof tests get recently an increased attention. Numerical simulation is expected in the coming years to accompany engineers in their design work to increase the chance of success in the fireproof certification tests. The current research focuses on the numerical investigation of a premixed methane-air flame imp...

متن کامل

Diagnosis of Heating , Ventilation and AirConditioning

Faults in heating, ventilation and air conditioning (HVAC) systems often go unde-tected because they are corrected by control loops at the expense of decreased ee-ciency. We present an experimental system which diagnoses faults based on measurements of system behavior and a model of its structure. It is based on model-based diagnosis techniques and could be used on-line to alert building manage...

متن کامل

Transpired solar collectors for ventilation air heating

g1 Richard Hall MEng, AIEMA EngD Researcher, Steel Construction Institute, Surrey EngD in Environmental Technology, University of Surrey, Guildford, UK g2 Xiaoxin Wang MSc, PhD Research Fellow, Oxford Institute for Sustainable Development, Oxford Brookes University, Oxford, UK g3 Raymond Ogden DiplArch, PhD Professor, Oxford Institute for Sustainable Development, Oxford Brookes University, Oxfo...

متن کامل

Improvement of thermal performance of a solar chimney based on a passive solar heating system with phase-change materials

Passive solar systems such as solar chimneys need solar radiation in order to work. Therefore, they cannot present stable natural ventilation when solar energy vanishes: to have a more robust and stable condition, solar energy should be stored during the day and released back during the night. Phase change materials can save additional thermal energy during the day and release it during the nig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2022

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202235601038