Heat transfer to non-azeotropic mixtures of refrigerants flowing in a horizontal evaporator tube.
نویسندگان
چکیده
منابع مشابه
Heat Transfer Efficiency of Turbulent Film Boiling on a Horizontal Elliptical Tube with External Flowing Liquid
Film boiling on a horizontal elliptical tube immersed in external flowing nitrogen liquid is investigated in the present paper. The isothermal wall temperature is high enough to induce turbulent film boiling, and then a continuous vapor film runs upward over the surface. The high velocity of the flowing saturated liquid at the boundary layer is determined by potential flow theory. In addition, ...
متن کاملGenetic optimization of heat transfer correlations for evaporator tube flows
Two-phase heat transfer coefficients for internal flows play a critical role in the design and analysis of evaporators and condensers. Previous studies propose empirical relations that combine the effects of nucleate and convective boiling onto the overall heat transfer coefficient. Although these relatively simple empirical relations offer physical insight on the nucleation, boiling and flow p...
متن کاملFlow Boiling Heat Transfer of Binary Mixtures HFO1234yf/R32 in a Smooth Horizontal Tube
HFO1234yf is a promising alternative for automobile air conditioners because of its low GWP of 4 and thermophysical properties similar to those of R134a. However, its performance is inferior to R410A. This makes it difficult to be applied to residential air-conditioners. A mixture of HFO1234yf and R32 is expected to balance both the GWP and COP requirement when applied to residential air-condit...
متن کاملHeat Transfer, Mass Transfer and Scaling Characteristics in a Long Tube, Climbing Film, Pilot Plant Evaporator
ing characteristics could be investigated. Finally the pilot plant A single tube plant Kestner evaporator'was set up at was run under 1st effect conditions in order that a comparison Illovo to investigate heat transfer characteristics when could be made with industrial 1st effect evaporators (both simulating different evaporator Tests carried out have Roberts and Kestner). This particular trial...
متن کاملIn Tube Evaporation Heat Transfer of Refrigerant Mixtures
Heat transfer coefficient data was taken during in-tube evaporation of five differenct refrigerant mixtures. These measurements were performed in a 318" O.D. (9.7 mm) smooth copper tube at refrigerant temperatures of -zoe and 4°C. Four different mass fluxes ranging from 125 to 375 kg/s-m2 were tested. On a mass basis, the five different mixtures tested were: R-125 (40%) I R-32 (60%), R-32 (30%)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
سال: 1990
ISSN: 0387-5016,1884-8346
DOI: 10.1299/kikaib.56.1084