Heat Transfer from a Horizontal Cylinder at Small Grash of Numbers
نویسندگان
چکیده
منابع مشابه
On the natural convective heat transfer from a cold horizontal cylinder over an adiabatic surface
A steady two-dimensional laminar free convection heat transfer from a cold horizontal isothermal cylinder located above an adiabatic floor is studied both experimentally and numerically. In the experimental measurements the effects of cylinder distance from horizontal floor to its diameter (L/D) on heat transfer coefficient is studied for Rayleigh numbers of 3×105 and 6×105. Computations are ma...
متن کاملon the natural convective heat transfer from a cold horizontal cylinder over an adiabatic surface
a steady two-dimensional laminar free convection heat transfer from a cold horizontal isothermal cylinder located above an adiabatic floor is studied both experimentally and numerically. in the experimental measurements the effects of cylinder distance from horizontal floor to its diameter (l/d) on heat transfer coefficient is studied for rayleigh numbers of 3×105 and 6×105. computations are ma...
متن کاملNatural Convection Heat Transfer From Horizontal Cylinders in a Vertical Arra Confined Between Parallel Walls
Laminar natural convection from an array of horizontal isothermal cylinders confined between two vertical walls, at low Rayleigh numbers, is investigated by theoretical and numerical methods. The height of the walls is kept constant, however, number of the cylinders and their spacing, the distance between the walls and Rayleigh number have been varied. The optimal spacing (confining walls) and ...
متن کاملTwo Phase Heat Transfer Characteristics in a Vertical Small Diameter Tube at Sub Atmospheric Pressure
Two-phase heat transfer is experimentally examined through vertical small diameter tubes, D =1.45 and 2.8 mm using water under a pressure of 50 to 81 kPa and a natural circulation condition. The pool boiling correlation by Stephan-Abdelsalam and the thermosyphon boiling correlation by Imura, et al. predict the measured experimental data in the 2.8 mm tube with an error of -30%. A large heat tra...
متن کاملHeat transfer from a cylinder in axial turbulent flows
Local convective heat transfer coefficients were measured on a two-diameter long cylinder in axial flows of air at conditions unexplored so far, by using thermochromic liquid crystals (TLC) coated on an electrically heated strip-foil consisting bonded to the external surfaces. The Reynolds numbers (Re) based on the cylinder diameter were between 8.9 · 10 and 6.17 · 10, and the flow in front of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Japan Society of Mechanical Engineers
سال: 1968
ISSN: 0029-0270,2185-9485
DOI: 10.1299/kikai1938.34.331