Heat transfer enhancement in tubular heat exchanger with double V-ribbed twisted-tapes

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger

If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...

متن کامل

Factor Effect Estimation in the Convective Heat Transfer Coefficient Enhancement of Al2O3/EG Nanofluid in a Double-pipe Heat Exchanger

The forced convective heat transfer (CHT) coefficient of a particular nanofluid, Al2O3 nanoparticles-ethylene glycol (EG) mixture, was investigated experimentally in a double-pipe heat exchanger. The nanofluid Nusselt number for different nanoparticles’ concentrations as well as various operating temperatures was measured to be increased up to 23.7% using 1.0% wt of nanoparticles. The significa...

متن کامل

evaluation of twisted tapes performance in enhancement of condensing heat transfer and pressure drop

in this research, heat transfer enhancement and simultaneous effect of that on pressure drop inside condensers with twisted tape inserts are investigated. a refrigeration system is designed for attaining to maximum level of heat transfer with minimum pressure drop. the test condenser is a double pipe heat transformer with inner and outer diameter of 10.7mm and 12.7mm for internal pipe, respecti...

متن کامل

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

In the present study, the heat transfer coefficients of benzene in a spiral plate heat exchanger are investigated. The test section consists of a Plate of width 0.3150 m, thickness 0.001 m and Mean hydraulic diameter of 0.01 m. The mass flow rate of water (Hot fluid) is varying from 0.5 kg sec to 0.8 kg sec and the mass flow rate of benzene (cold fluid) varies from 0.4 kg sec to 0.7 kg sec. Exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Case Studies in Thermal Engineering

سال: 2016

ISSN: 2214-157X

DOI: 10.1016/j.csite.2016.01.002