HEAT TRANSFER ENHANCEMENT AND PRESSURE DROP OF GROOVED ANNULUS OF DOUBLE PIPE HEAT EXCHANGER
نویسندگان
چکیده
منابع مشابه
Heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملFactor Effect Estimation in the Convective Heat Transfer Coefficient Enhancement of Al2O3/EG Nanofluid in a Double-pipe Heat Exchanger
The forced convective heat transfer (CHT) coefficient of a particular nanofluid, Al2O3 nanoparticles-ethylene glycol (EG) mixture, was investigated experimentally in a double-pipe heat exchanger. The nanofluid Nusselt number for different nanoparticles’ concentrations as well as various operating temperatures was measured to be increased up to 23.7% using 1.0% wt of nanoparticles. The significa...
متن کاملHeat Transfer of Nanofluid in a Double Pipe Heat Exchanger
This paper investigates the enhancement of heat transfer coefficient and Nusselt number of a nanofluid containing nanoparticles (γ-AL2O3) with a particle size of 20 nm and volume fraction of 0.1%-0.3% (V/V). Effects of temperature and concentration of nanoparticles on Nusselt number changes and heat transfer coefficient in a double pipe heat exchanger with counter turbulent flow are investigate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Polytechnica
سال: 2017
ISSN: 1805-2363,1210-2709
DOI: 10.14311/ap.2017.57.0125