Heat transfer and structural response modelling of FRP confined rectangular concrete columns in fire
نویسندگان
چکیده
منابع مشابه
Compressive Strength Prediction by ANN Formulation Approach for FRP Confined Rectangular Concrete Columns
Enhancement of strength and ductility is the main reason for the extensive use of FRP (fiber reinforced polymer) jackets to provide external confinement to reinforced concrete columns especially in seismic areas. Therefore, numerous researches have been carried out in order to provide a better description of the behavior of FRP confined concrete for practical design purposes. This study present...
متن کاملBehavior of FRP-Confined Concrete-Filled Steel Tube Columns
This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap...
متن کاملBehavior of FRP-Confined Reactive Powder Concrete Columns under Eccentric Loading
Fiber reinforced Polymers (FRP) have widely used for the purposes of enhances strength and ductility of concrete columns. Proper design of such hybrid columns, however, requires a better recognition of the behavior of concrete columns confined with FRP. In this paper, the influence of FRP thickness, concrete compressive strength, and column size on the performance of eccentrically loaded reacti...
متن کاملCompressive Strength of Confined Concrete in CCFST Columns
This paper presents a new model for predicting the compressive strength of steel-confined concrete on circular concrete filled steel tube (CCFST) stub columns under axial loading condition based on Artificial Neural Networks (ANNs) by using a large wide of experimental investigations. The input parameters were selected based on past studies such as outer diameter of column, compressive strength...
متن کاملBehaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns
This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with Carbon Fibre Reinforced...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Construction and Building Materials
سال: 2012
ISSN: 0950-0618
DOI: 10.1016/j.conbuildmat.2010.12.064