Heat Transfer and Pressure Drop of Finned Tube Banks with a Staggered Arrangement in Forced Convection. (1st Report. Heat Transfer Characteristics and Correlation of Spirally Finned Tube Banks).
نویسندگان
چکیده
منابع مشابه
Characteristics of forced convection heat transfer in vertical internally finned tube
This work presents a numerical investigation of a vertical internally finned tube subjected to forced convection heat transfer. The governing equations were solved numerically using the control volume technique. Nusselt number, Nu, and friction factor multiplied by Reynolds number, fRe, are influenced greatly by the height and number of the radial fins. The velocity and temperature distribution...
متن کاملNatural convection and radiation heat transfer of an externally-finned tube vertically placed in a chamber
A three-dimensional numerical study was made to investigate effects of fin angle, fin surface emissivity, and tube wall temperature on heat transfer enhancement for a longitudinal externally-finned tube placed vertically in a small chamber. The numerical model was first validated through comparison with experimental measurements and the appropriateness of general boundary conditions was examine...
متن کاملA numerical investigation of γ-Al2O3-water nanofluids heat transfer and pressure drop in a shell and tube heat exchanger
The effect of γ-Al2O3 nanoparticles on heat transfer rate, baffle spacing and pressure drop in the shell side of small shell and tube heat exchangers was investigated numerically under turbulent regime. γ-Al2O3-water nanofluids and pure water were used in the shell side and the tube side of heat exchangers, respectively. Since the properties of γ-Al2O3-water nanofluids were variable, they were ...
متن کاملEffective Heat Transfer Enhancement in Finned Tube Heat Exchanger with Different Fin Profiles
During cross flow in a heat exchanger, heat transfer in the front portion of the tube is more compared to back portion of the tube. This is due to less formation of vortices at the backside of the tube. For uniform heat transfer to take place throughout the tube, it is necessary to increase the vortex formation at the rear side of the tube. The aim of this study is to explore the possibilities ...
متن کاملFriction Loss and Heat Transfer Coefficient in Finned Tube Heat Exchangers for Reheating Massecuites
Equations developed for packed columns may be used to predict the overall heat transfer coefficient and friction loss in massecuite reheaters. The results seem to indicate that exchangers with the tubes staggered give higher heat transfer rates than those with the tubes in line.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
سال: 1991
ISSN: 0387-5016,1884-8346
DOI: 10.1299/kikaib.57.1752