Estimation of Heat Release in Fire Compartment

This paper presents the model to estimate heat release in fire compartment about four fuels, Douglas fir considering char formation and moisture content, methanol, methane and propane, with equivalence ratio Q on the basis of previous work and discusses about the difference of the combustion efficiency of them. As the result, calculated heat release of Douglas fir, methane and propane shows rel...

متن کامل

Heat release of polymer composites in fire

The relationship between heat release rate and other fire reaction properties of fibre reinforced polymer composite materials is investigated. The heat release rate and fire reaction properties of thermoset matrix composites reinforced with combustible fibres (aramid, extended-chain polyethylene) or non-combustible fibres (glass, carbon) were determined over a range of heat flux levels using th...

متن کامل

A New Investigation on Tunnel Pool Fire Phenomenon Using CFD Technique

In this study, the amount of generated pool fire, as a result of the release of chemicals in the case of an accident in tunnels, was simulated and the results were compared to the experimental data. At first, various amounts of spatial resolution (R*) were considered to compare the existing experimental data at different heights at the upstream, downstream and above the pool fire...

متن کامل

Dominance in hands and cross-sectional area of median nerve in carpal tunnel syndrome

Introduction: Currently, neuroresearchers report that the median nerve shows severity-correlated intracarpal enlargement in idiopathic carpal tunnel syndrome (CTS) as a most common peripheral neuropathic disorder. The purpose of this paper was to investigate ultrasonography morphological findings in patients with idiopathic CTS and comparing some physical properties such as age, gender, BMI wit...

متن کامل

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

In the Far East, many small units of residential buildings over 200 m tall are fitted with open kitchens. Fire safety provisions of these kitchens are determined by performance-based design (PBD). In most PBD projects, only the spread of smoke from the kitchen fire to the outside was studied. However, a fire load survey in Hong Kong indicated that large quantities of combustibles are stored in ...

متن کامل