Heat Pump System with R22/R114 Mixtures as Working Fluids. 2nd Report. Experiment on Double-Tube Evaporator and Condenser with Grooved Tubes.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Model of an Air-Conditioning Condenser and Evaporator with Emphasis on In-Tube Enhancement

A MODEL OF AN AIR-CONDITIONING CONDENSER AND EVAPORATOR WITH EMPHASIS ON IN-TUBE ENHANCEMENT Kuo-Hsiu Huang Michael B. Pate Mechanical Engineering Department Iowa state University Ames, Iowa 50011 A computational model for air-conditioning condensers and evaporators with in-tube enhancement has been developed. The purpose of this model is to provide a tool for the design of plate tinned-tube he...

متن کامل

Refrigerant Circuit Optimization of Dual-mode Single-Row Microchannel Heat Exchangers used for R410A Heat Pumps

Microchannel heat exchangers (MCHX) are being increasingly applied in heat pumps because of their compactness, significant charge reduction, lower refrigerant pressure drop and lower air-side fan power consumption compared to traditional round tube-plate fin (RTPF) heat exchangers. Using a microchannel condenser as well as evaporator in a heat pump system also offers significant potential for c...

متن کامل

Design Method Of Steady State Detector For Multi-Evaporator Heat Pump System With Decomposition Analysis Technique

Recent market trend of eco-friendly products let the manufacturers be ready for the high quality of maintenance technologies to assure the system’s high efficiency during its entire life span. However, this post-manufacturing activities burden the manufacturer with high warranty cost. Therefore, in order to promote economical businesses, the manufacturers are developing various fault detection ...

متن کامل

Experimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids

This paper presents the experimental investigations conducted on a vertical closed loop pulsating heat pipe (VCLPHP) to evaluate the thermal performance. The values of thermal resistance and heat transfer coefficient obtained in the experimentation is used as evaluation parameters. The VCLPHP used has capillary tubes having an inner diameter of 2mm and outside diameter 3mm and bent into 5 turns...

متن کامل

Multi-response Optimization of Grooved Circular Tubes Filled with Polyurethane Foam as Energy Absorber

The main objective of this research is to improvethe design and performance of the polyurethane foam-filled thin-walled aluminum grooved circular tubes using multi-response optimization (MRO) technique. The tubes are shaped with the inner and the outer circular grooves at different positions along the axis. For this aim, several numerical simulations using ABAQUS finite element explicit code ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B

سال: 1991

ISSN: 0387-5016,1884-8346

DOI: 10.1299/kikaib.57.2377