Haunch Retrofitting of Exterior Beam-Column Connection
نویسندگان
چکیده
منابع مشابه
Retrofitting of Beam-Column Joint Using CFRP and Steel Plate
─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...
متن کاملEvaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)
The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...
متن کاملPerformance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملFinite element analysis of a rigid beam to column connection reinforced with channels
Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...
متن کاملSeismic Behavior of Prefabricated Column-Footing Connection
Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2019
ISSN: 2321-9653
DOI: 10.22214/ijraset.2019.8124