Harmonics elimination for DC/DC power supply based on piezoelectric filters

نویسندگان

چکیده

This research presents a study, modelling and simulation of the piezoelectric material work as filters (piezoelectric filter) used to eliminate harmonics in power electronic circuits, high order are generating due switching frequencies circuit equipment, detailed is achieved for filter tested full-bridge DC/DC converter with resistive load works dc supply (12 48 volt). As result, uses have great impact on elimination, which leads reduce overall total harmonic distortion increase efficiency, well output voltage from remain constant by varying resistance over wide range. The including has been simulated using PSIM (V9.1) software.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Most of the pollution issues created in power systems are due to the non-linear characteristics and fast switching of power electronic equipment. Power quality issues are becoming stronger because sensitive equipment has been more sensitive for market competition reasons, equipment will continue polluting the system more and more due to cost increase caused by the built-in compensation and some...

متن کامل

Harmonics Mitigation of Industrial Power System Using Passive Filters

With the development of modern industrial technology a large number of non-linear loads are used in power system, which causes harmonic distortion in the power system. At the same time the power quality and safe operation becomes inferior. Therefore mitigation of harmonics is very necessary under the situation. This paper presents the design of two passive filters to reduce the current harmonic...

متن کامل

Standby - Loss Elimination in Server Power Supply †

In a server power system, a standby converter is required in order to provide the standby output, monitor the system’s status, and communicate with the server power system. Since these functions are always required, losses from the standby converter are produced even though the system operates in normal mode. For these reasons, the losses deteriorate the total efficiency of the system. In this ...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Power Electronics and Drive Systems

سال: 2021

ISSN: ['2722-2578', '2722-256X']

DOI: https://doi.org/10.11591/ijpeds.v12.i1.pp356-363