Harmonic resonance on parallel high voltage transmission lines

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests

In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...

متن کامل

Proximity Effects of High Voltage Transmission Lines on Humans

Recently new threats to humans are observed from electromagnetic radiation from various sources like mobile phones, transmission lines and many more. For providing continuous and uninterrupted supply of electric power to consumer’s maintenance operation of high voltage power lines are often performed with systems energized or live. This is referred as Hot Line maintenance or live line maintenan...

متن کامل

Solving Harmonic Resonance Problems on the Medium Voltage System

Harmonic problems are increasing on MV systems, especially with the application of power factor correction capacitors or extensive underground networks that resulting resonances close to the fifth harmonic. This paper describes two case studies of solving harmonic resonance problems on distribution systems with the design of harmonic filters that provide both power factor correction and harmoni...

متن کامل

Impact of Untransposed 66kV Sub-transmission Lines on Voltage Unbalance

The level of voltage unbalance that exists in some interconnected sub-transmission networks in Australia has been observed to be above the code requirements (e.g. 1% in Victoria). There is a perception that these high levels arise as a result of asymmetrical loads. However, the system asymmetry (of lines which are not normally transposed at 66kV, transformers and capacitor banks) also can play ...

متن کامل

Monte Carlo method for estimating backflashover rates on high voltage transmission lines

This paper presents a novel Monte-Carlo based model for the analysis of backflashover rate (BFOR) on high voltage transmission lines. The proposed model aims to take into the account following aspects of the BFOR phenomenon: transmission line (TL) route keraunic level(s), statistical depiction of lightningcurrent parameters (including statistical correlation), electrogeometric model of lightnin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 1997

ISSN: 0885-8977

DOI: 10.1109/61.568274