Harmonic Loss Analysis of the Traction Transformer of High-Speed Trains Considering Pantograph-OCS Electrical Contact Properties
نویسندگان
چکیده
منابع مشابه
Harmonic Loss Analysis of the Traction Transformer of High-Speed Trains Considering Pantograph-OCS Electrical Contact Properties
The traction transformer of the traction drive system of a high-speed train is one of the main equipments for energy conversion. The transformer loss will be increased by load harmonics and pantograph arcs at high speed. It is very important to predict losses for the improvement of traction transformer design. In this paper, a dynamic model of the pantograph-catenary system is established using...
متن کاملNew Designing Procedure for Pantograph of High-Speed Trains
In Japan, several projects to increase train speed are underway, requiring a new generation pantograph that achieves further reduction in aerodynamic noise. However, as reduction of pantograph noise usually conflicts with the stabilization of its lift force characteristics, a number of experiments have to be conducted to develop a new type of pantograph. The aeroacoustic and lift force characte...
متن کاملMultiple Pantograph Interaction with Catenaries in High-Speed Trains
This work presents a fully three-dimensional methodology for the computational analysis of the interaction between catenary and pantographs. The finite element method is used to support the modeling of the catenary while a multibody dynamics methodology is applied to support the pantograph modeling. The contact between the two subsystems is described using a penalty contact formulation. An high...
متن کاملcontrol of the optical properties of nanoparticles by laser fields
در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...
15 صفحه اولStudy on Friction and Wear Properties of Pantograph Strip/Copper Contact Wire for High-Speed Train
A series of experiments on friction and wear properties of carbon strip rubbing against copper contact wire is performed on high-speed friction and wear tester with electric current. The results show that the friction coefficient is generally maintained between 0.24 and 0.37. In the absence of electric current, the coefficient of friction is higher than that in the presence of electric current....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2013
ISSN: 1996-1073