Harmonic Effects on Electromechanical Overcurrent Relays

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling Electromechanical Overcurrent Relays Using Singular Value Decomposition

This paper presents a practical and effective novel approach to curve fit electromechanical EM overcurrent OC relay characteristics. Based on singular value decomposition SVD , the curves are fitted with equation in state space under modal coordinates. The relationships between transfer function and Markov parameters are adopted in this research to represent the characteristic curves of EM OC r...

متن کامل

Line Protection with Overcurrent Relays

259 Lines are protected by overcurrent-, distance-, or pilot-relaying equipment, depending on the requirements. Overcurrent relaying is the simplest and cheapest, the most difficult to apply, and the quickest to need readjustment or even replacement as a system changes. It is generally used for phaseand ground-fault protection on station-service and distribution circuits in electric utility and...

متن کامل

A Fuzzy Approach for Overcurrent Relays Simulation

Accurate models for Overcurrent relays (OC) with inverse time characteristics have an important role for efficient coordination of power system protection devices. This paper proposes a new method for modelling of OC relays based on fuzzy logic. The new model is more accurate than traditional models and has been validated by comparing it with the linear and nonlinear analytical models.

متن کامل

Providing A New Characteristic for Overcurrent Relays

This with the integration of distributed generation (DG) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance DG tripping. This paper proposes a new tripping characteristic for directional overcurrent relays (DOCRs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...

متن کامل

Directional Overcurrent Relays Coordination Problems in Distributed Generation Systems

This paper proposes a new approach to the distributed generation system protection coordination based on directional overcurrent protections with inverse-time characteristics. The key question of protection coordination is the determination of correct values of all inverse-time characteristics coefficients. The coefficients must be correctly chosen considering the sufficiently short tripping ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Doğuş Üniversitesi Dergisi

سال: 2005

ISSN: 1302-6739

DOI: 10.31671/dogus.2019.272