Harmonic Analysis of Fuzzy Logic Controller Based Active Filter Unit Using Resonant Current Control in Distributed Power System
نویسندگان
چکیده
منابع مشابه
Harmonic Mitigation using Fuzzy Logic Controller based Shunt Active Power Filter
Power quality problem is t he most sensitive problem in the power system. The objective of the project is to reduce one of the power quality issue called “harmonics” using compensation technique. Shunt Active Power Filter (SAPF) is used to eliminate harmonic current and also it compensates reactive power. In this project, both PI controller and Fuzzy Logic Controller based three-phase shunt act...
متن کاملA Fuzzy Logic Based Controller for Shunt Power Active Filter
This paper deals with the use of shunt active filter to compensate current perturbations produced by non linear loads. To perform the identification of disturbing currents, the so called Instantaneous Active and Reactive Power Method (pq) is used. A Phase Locked Loop (PLL) circuit, locked to the fundamental frequency of the system voltage, is also introduced for eventual mains voltages perturba...
متن کاملApplication of Fuzzy Logic Controller in Shunt Active Power Filter
This paper presents application of fuzzy logic controller for shunt active power filter to improve power quality in the distribution systems. The main feature of fuzzy logic controller does not require any complex mathematical model of the systems to regulate dc bus capacitor voltage. The reference compensating current has been estimated by unit vector template generation technique. The actual ...
متن کاملActive Suspension System Control Using Adaptive Neuro Fuzzy (ANFIS) Controller
The purpose of designing the active suspension systems is providing comfort riding and good handling in different road disturbances. In this paper a novel control method based on adaptive neuro fuzzy system in active suspension system is proposed. Choosing the proper data base to train the ANFIS has an important role in increasing the suspension system’s performance. The data base which is used...
متن کاملA Comparative Analysis of PI Controller and Fuzzy Logic Controller for Hybrid Active Power Filter Using Dual Instantaneous Power Theory
This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase systems. The Hybrid active power filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Hybrid Active Power filter is able to operate in balanced, load conditions. Classic filters may...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Engineering & Technology
سال: 2018
ISSN: 2227-524X
DOI: 10.14419/ijet.v7i3.31.18199