Haematocrit and the Boehringer Advantage Blood Glucose Meter
نویسندگان
چکیده
منابع مشابه
Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملLaboratory evaluation of the Glucocard blood glucose test meter.
The Glucocard (Kyoto Daiichi Kagaku) blood glucose meter is designed for self-monitoring of blood glucose concentrations in capillary blood through use of an electrochemical test strip. Evaluated in this laboratory, the Glucocard had CVs of 4.6%, 6.6%, and 3.5% at blood glucose concentrations of 2.4, 4.1, and 18.9 mmol/L, respectively. The meter's response varied linearly with blood glucose con...
متن کاملBlood glucose measurement with Dextrostix and new reflectance meter.
A new instrument, Eyetone, has been produced for use with a Dextrostix reagent strip for estimating blood sugar levels. It differs from the Dextrostix Reflectance Meter in having only one meter scale, a two-point calibration, and a range of measurement limited to 10-400 mg/100 ml. Results with the manufacturers' original calibration were unsatisfactory, but when recalibrated the performance of ...
متن کاملImportance of blood glucose meter and carbohydrate estimation accuracy.
BACKGROUND The clinical significance of blood glucose meter (BGM) error in the presence of increasing carbohydrate errors in diabetes patients who use both the BGM result and the carbohydrate estimation to dose insulin is unknown. METHODS This Monte Carlo simulation modeled diabetes patients who calculate insulin dosages based on BGM results and carbohydrate estimations. It evaluated the like...
متن کاملMonitoring neonatal hypoglycemia with the Accu-chek advantage II glucose meter: the cautionary tale of galactosemia.
To the Editor: Hand-held glucose meters are a practical solution for measuring glucose in neonatal intensive care units and special care nurseries because of their portability, the immediacy of results, and minimal blood volume requirements compared with dispatching samples for central laboratory analysis. We have used the Roche Accu-chek Advantage II meter for some time in our neonatal intensi...