Microbial H2O2 sensors as archetypical redox signaling modules.
The Saccharomyces cerevisiae Orp1–Yap1 sensor and its prokaryotic counterpart OxyR are master regulators of cellular H2O2 homeostasis. These sensors share a stereotypical mechanism, involving the reaction of a unique cysteine with H2O2 and a physiology coupled to metabolism of H2O2 and thiol reduction–oxidation (redox). However they differ fundamentally in their core mechanism. Whereas OxyR car...
متن کاملIntegrated Sensors in Biological Environments*
This paper reviews the application and operation of integrated sensors and actuators in biological and physiological environments. Integrated transducers are widely employed for invasive and non-invasive patient monitoring, for recording and understanding biological events and systems, for delivery of chemicals and electrical stimuli into the body, and as a means for eventual realization of clo...
متن کاملModern Directions for Potentiometric Sensors.
This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection ...
متن کاملScreen Printed Potentiometric Chloride Sensors
Potentiometric chloride sensors were fabricated by electrochemically chloridizing the surface of screen printed silver electrodes using amperostatic coulometry or asymmetric square wave voltammetry. In the case of coulometric chloridization, the effect of different chloride ion sources was also investigated. The response to chloride ions by each type of sensor was determined by measuring their ...
متن کاملpH-based Detection of Phenylalnine by Potentiometric and Colorimetric Methods
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results ...